| 1.0 |
SCOPE |
| |
1.1 |
This specification covers a jacketed
cable containing two UL listed
Sprinkler Systems Wires, single
conductor, suitable for direct burial,
for operation up to 600 volts, and
temperatures up to 60°C. |
| |
|
|
| 2.0 |
CONSTRUCTION: |
| |
2.1 |
Inner Conductors: |
| |
|
Soft drawn bare copper meeting the
requirements of ASTM specification
B-3 or B-8. Insulation shall be low
density high molecular weight polyethylene
and a thickness of 0.045",
per Paige Electric specification
P7079D. The two conductors (black
and white) shall be twisted with a
minimum lay of 4". |
| |
2.2 |
Overall jacket: |
| |
|
Red, high density polyethylene with
a thickness of 0.035". Available
with optional identification stripe
colors as listed in the table below.
Stripe to be integrally extruded into
and through the complete wall of the
jacket with an approximate width of
1/8". The jacket shall be sufficiently
round, and loose, to facilitate its
removal when being stripped. |
|
|
| |
2.3 |
Surface Print: |
| |
|
2.31 |
Inner Conductors –
"Paige Electric P7079D 14 or 12 AWG PE UL Number 600V Sprinkler System
Wire Direct Burial" |
| |
|
2.32 |
Outer Jacket – "Paige Electric,
P7350D, 14 or 12 AWG PE UL Number
600V Sprinkler System Wire
Direct Burial Only for Toro
Decoder Systems RoHS" |
| |
|
|
| 3.0 |
TEMPERATURE RATING |
| |
3.1 |
-55°C to +60°C |
| |
|
|
| |
|
|
| 4.0 |
SPLICING RECOMMENDATIONS |
| |
4.1 |
3M DBY-6 or DBR-6
connectors. |
|