These products were specifically designed as electrical isolation devices to help with troubleshooting of damaged or non-functioning 2-Wire irrigation systems. Single or multiple sections of the electrical circuit can be disconnected or isolated by simply removing a fuse, without cutting wires or undoing splices/joints. Patent Pending.

Quick-disconnect Splitter – Splits the incoming signal from the central computer into two (270DCFD) or three (270DCFD3) directions. See wiring diagrams.

Wiring diagrams:

Fuses – Standard 20-amp Mini Automotive fuses are utilized to act as circuit switches when they are inserted (closed/on) or removed (open/off.)  The fuses also provide lightning protection when the electrical surges exceed the capacity of the 20-amp fuse(s.)  The isolation of circuit sections eliminates or minimizes electronic component failure.

Test Posts – These posts (red dots in the Wiring diagrams) are accessible when the threaded cap is removed.  This allows the measurements of voltage and current flow.  It may be necessary to use a “True RMS” multi-meter to perform these tests.  Consult with the manufacturer of the decoder system.

Water Tight – A resin is used to waterproof the wire leads.

Wire Leads – All wires are 14 AWG, Type UF/TWU direct burial, 36” long.  This allows the assembly to be brought above grade when troubleshooting and accessing the fuses.

O-Ring Seal – Provides a waterproof capsule.  Cap is unscrewed to access the fuses.

ACME Threads – Minimizes binding of threads due to soil.

Splices/joints - All connections of the 14 AWG wire leads onto the 2-wire cables shall be made using a 3M model DBR/Y-6 (Paige Electric 270672.)

Product Dimensions:

Model Diameter Height
270DCFD 2-3/16" 3-1/16"
270DCFD3 2-3/8" 3-1/4"

Packaging:

Part Number Quantity per case Pounds Each Box Dimensions
270DCFD 5 1.0 9" x 12" x 5"
270DCFD3 1.25

Typical Specifications:

The Paige Electric Decoder Cable Fuse Devices shall be installed at strategic locations of a Decoder/2-Wire/2-Core system such that it can isolate certain sections of cables for purposes of troubleshooting.  The DCFD shall be installed inside an accessible irrigation valve box.  Each location shall be clearly shown on the as built drawings.  The splices for all connections shall be made using 3M model DBR/Y-6 (Paige Electric 270672) waterproof connectors.

Typical Installation:

Typical Installation
Note that the Decoder Cable Fuse Devices have been strategically installed at the points where cables split in different direction. These are the obvious location that one would undo the splices when troubleshooting and trying to isolate the section of the system that is causing the fault.