1.0 SCOPE:
1.1 This specification covers single conductor insulated wire sizes 14 AWG, through 10 AWG, utilizing low density high molecular weight polyethylene insulation, twisted, suitable for direct burial applications for operation up to 600 volts and conductor temperatures up to 60°C. UL listed.
2.0 CONSTRUCTION:
2.1 Conductor:
Soft drawn bare copper meeting the requirements of ASTM specification B-3 or B-8
2.2 Temperature Rating:
-55ºC +66ºC
2.3 Insulation:
Insulation thickness shall be 0.060”. Conductor colors are black, red and reduced green. Conductors shall be twisted with a 4" lay.
2.4 Manufacturer's Identification:
Surface marked with Paige-Electric, PE-60, voltage rating, size and type, and UL file number.
2.5 Underwriters' Laboratories Approval:
All cables shall be tested physically and electrically in accordance with UL Standard 493, and 83 (paragraphs 28.1, 29.1 and 29.2). All reels and cartons bear UL labels.
2.6 Tests:
Material must be able to pass the following tests without showing signs of degradation.
2.6.1 COLD BEND:
The insulation shall not show any cracks when sample is bent around a mandrel of 3 x wire diameter, after being subjected to -55°C ± 1°C for one (1) hour.
2.6.2 ELECTRICAL:
AC test voltage, 5 minutes at 3,000 volts.
2.6.3 ENVIRONMENTAL AGING:
Immersed for 14 days in concentrated solutions of fertilizers, herbicides and insecticides.
2.7 Splicing Recommendations:
Splicing can be accomplished using Paige Electric DBM, or 3M DBY connectors. PVC adhesives or sealing compounds are not recommended.
2.8 Paige Part Numbers:
14/14/14 AWG
12/12/14 AWG
10/10/14 AWG
150531
150532
150353
 