| 1.0 |
SCOPE: |
|
1.1 |
This specification covers construction requirements for a
2-conductor control cable design consisting of bare copper conductors,
insulated with PVC and having a high density polyethylene direct burial
jacket. Conductors are listed as low energy circuit cable. |
| |
|
|
| 2.0 |
CONSTRUCTION: |
|
2.1 |
|
|
NO. OF
COND. |
SIZE
(AWG) |
INS. WALL
(MILLS) |
JACKET WALL
(MILLS) |
O.D. |
WEIGHT
LBS/M |
| 2 |
14 |
45 |
30 |
.214" x
.368" |
63 |
| 2 |
16 |
45 |
30 |
.190" x
.320" |
40 |
| 2 |
18 |
45 |
30 |
.190"
x .320" |
40 |
|
| |
|
|
2.2 |
Conductor: |
|
|
Soft annealed bare solid copper conforming to
ASTM B-33. |
| |
|
|
|
2.3 |
Insulation: |
|
|
Polyvinyl Chloride conforming to UL Standard
493 rated 60°C. |
| |
|
|
| |
2.4 |
Cable Assembly: |
| |
|
Insulated conductors are laid parallel. |
|
|
| |
2.5 |
Outer Jacket: |
| |
|
PPressure Extruded High Density PE conforming to ICEA S-61-402, and
NEMA WC5 Jacket Thickness 2/64" minimum jacket material to completely
fill interstices between the two insulated conductors. UV Resistant. |
| |
|
|
| |
2.6 |
Conductor Color Coding: |
| |
|
Black, Red |
| |
|
|
| |
2.7 |
Jacket Color: |
| |
|
Several |
| |
|
|
| |
2.8 |
Surface Print: |
| |
|
“Paige Electric P7296D Size Sunlight Resistant Direct Burial For
Tucor Control Systems” RoHS. |
| |
|
|
| 3.0 |
SPLICING RECOMMENDATIONS: |
| |
Wire splices are the weak link of any electrical
circuit. It is especially important to make proper joints in irrigation
systems because the joints are exposed to wet and damp environments that
can cause corrosion of the copper conductor, and premature failure.
Paige Electric recommends the strict use of Model DBR/Y-6, as
manufactured by the 3M Company (Paige specification P7364D) |
|