P.O. Box 368, Union, NJ 07083-0368, 908-687-7810, 800-327-2443, Fax: 908-687-8860

Download printable PDF version

SPECIAL IRRIGATION
TUCOR CONTROL CABLE
14/2 - 18/2 DIRECT BURIAL
INSULATION: POLYVINYL CHLORIDE
JACKET: POLYETHYLENE
SIZES: 14, 16, 18 AWG, 2 CONDUCTOR

1.0 SCOPE:
1.1 This specification covers construction requirements for a 2-conductor control cable design consisting of bare copper conductors, insulated with PVC and having a high density polyethylene direct burial jacket. Conductors are listed as low energy circuit cable.
     
2.0 CONSTRUCTION:
2.1
NO. OF
COND.
SIZE
(AWG)
INS. WALL
(MILLS)
JACKET WALL
(MILLS)
O.D. WEIGHT
LBS/M
2 14 45 30 .214" x .368" 63
2 16 45 30 .190" x .320" 40
2 18 45 30 .190" x .320" 40
   
2.2 Conductor:
Soft annealed bare solid copper conforming to ASTM B-33.
     
2.3 Insulation:
Polyvinyl Chloride conforming to UL Standard 493 rated 60°C.
     
  2.4 Cable Assembly:
    Insulated conductors are laid parallel.
  2.5 Outer Jacket:
  PPressure Extruded High Density PE conforming to ICEA S-61-402, and NEMA WC5 Jacket Thickness 2/64" minimum jacket material to completely fill interstices between the two insulated conductors. UV Resistant.
     
  2.6 Conductor Color Coding:
  Black, Red
     
  2.7 Jacket Color:
  Several
     
  2.8 Surface Print:
  “Paige Electric P7296D Size Sunlight Resistant Direct Burial For Tucor Control Systems” RoHS.
     
3.0 SPLICING RECOMMENDATIONS:
  Wire splices are the weak link of any electrical circuit. It is especially important to make proper joints in irrigation systems because the joints are exposed to wet and damp environments that can cause corrosion of the copper conductor, and premature failure. Paige Electric recommends the strict use of Model DBR/Y-6, as manufactured by the 3M Company (Paige specification P7364D)