| 1.0 |
SCOPE: |
|
1.1 |
This specification covers construction
requirements for a 2/C control cable design
to operate valve decoders consisting of bare
copper conductors, insulated with PVC and
having a high density polyethylene direct
burial jacket. Conductors are UL listed low
energy circuit wire. |
| 2.0 |
CONSTRUCTION: |
|
2.1 |
|
NO. OF
COND. |
SIZE
(AWG) |
STRAND |
INS. WALL
(MILLS) |
JACKET WALL
(MILLS) |
O.D. |
WEIGHT
LBS/M |
| 2 |
14 |
1 |
45 |
30 |
.214" x
.368" |
63 |
| 2 |
16 |
1 |
45 |
30 |
.190" x
.320" |
40 |
| 2 |
18 |
1 |
45 |
30 |
.190"
x .320" |
40 |
|
|
2.2 |
Conductor: |
|
|
Soft annealed bare copper conforming to
ASTM B-33. |
|
2.3 |
Insulation: |
|
|
Polyvinyl Chloride conforming to UL Standard
493 rated 60°C. |
|
|
| 2.4 |
Cable Assembly: |
|
Insulated conductors are laid parallel. |
| 2.5 |
Outer Jacket: |
|
Pressure Extruded High Density PE
conforming to ICEA S-61-402, and
NEMA WC5 Jacket Thickness 2/64"
minimum jacket material to completely fill
interstices between the two insulated
conductors. UV Resistant. |
| 2.6 |
Color Coding: |
|
Black, Red |
| 2.7 |
Jacket Color: |
|
Color coding of jacket shall be of one solid
color. Green. |
| 2.8 |
Surface Print: |
|
"Paige Electric P7296D Size
150V
Sunlight Resistant Direct Burial For Tucor Control Systems" |
|