P.O. Box 368, Union, NJ 07083-0368, 908-687-7810, 800-327-2443,
Fax: 908-687-8860
| 1.0 |
Scope: |
| |
1.1 |
This specification covers single conductor
insulated wires from 1.5mm² to 6.0mm²,
utilizing low density high molecular
weight polyethylene insulation, suitable
for direct burial applications for for
operating temperatures up to 60°C.
Listed by UL or ETL or CSA. |
| |
|
|
| 2.0 |
CONSTRUCTION: |
| |
2.1 |
Conductors: |
| |
|
Soft Drawn Bare Copper meeting the requirements of ASTM
B-3 or B-8. |
| |
|
|
| |
2.2 |
Temperature Rating: |
| |
|
-55°C to +60°C |
| |
|
|
| |
2.3 |
Construction Data: |
|
|
| CONDUCTOR SIZE |
CIRCULAR MIL AREA IN CIRCULAR MILS |
INSULATION THICKNESS |
| 1.5mm2 |
2960 |
1.15MM |
| 2.5mm2 |
4933 |
1.15MM |
| 4.0mm2 |
7893 |
1.15MM |
| 6.0mm2 |
11838 |
1.15MM |
|
| |
|
|
| |
2.4 |
Manufacturer’s Identification: |
| |
|
Surface marked with Paige Electric, voltage rating, size
and type, Listing file number, RoHS. |
|
|
| |
2.5 |
Listing: |
| |
|
All cables shall be tested physically and electrically
in accordance with UL Standard 493, and 83. All reels and
cartons bear Listing labels. |
| |
|
|
| 3.0 |
SPLICING RECOMMENDATIONS: |
| |
Wire splices are the weak link of any electrical
circuit. It is especially important to make
proper joints in irrigation systems because
the joints are exposed to wet and damp
environments that can cause corrosion of
the copper conductor and premature failure.
Here are Paige Electric’s recommendations:
- For direct burial, above ground, or in
valve box installations: Model DBR/Y-6 as
manufactured by the 3M Company (Paige
specification P7364D)
- For installation above ground or in
valve boxes: Models 316IR or MGC as
manufactured by the 3M Company (Paige
specification P7365D), or Silicone-filled wire
nuts as manufactured by IDEAL Industries
(Paige specification P7372D)
|
|