SHIELDED BURIED SIGNAL CABLE
INSULATION: POLYETHYLENE
JACKET: PE
SIZES: 18 AWG, 4 CONDUCTOR/2 PAIRS
p7171d11.jpg (6484 bytes)
Ullogo.gif (224 bytes)
1.0 SCOPE
1.1 This specification covers a multi-pair direct burial shielded cable designed to carry signals for Irrigation Control Equipment.
2.0 CONSTRUCTION
2.1
 
NO. OF
PAIRS
NO. OF
COND.
SIZE
(AWG)
STRANDS INSULATION
WALL
2 4 18 7 .015" HIGH DENSITY PE
2.2 Conductor:
Stranded soft annealed tin coated copper conforming to ICEA S-56-434.
2.3 Insulation:
High density Polyethylene conforming to ICEA S-56-434.
2.4 Cable Assembly:
Insulated conductors are twisted into a pair and the cabled together.
2.5 Color Coding:
Pair 1 - Red, Black
Pair 2 - Blue, Orange
2.6 Shield:
.00235" aluminum/mylar tape helically applied.
2.7 Drain Wire:
A 20 AWG tinned copper drain wire is laid in under the shield in contact with the aluminum side.
2.8 Jacket :
.045" PE jacket conforming to ICEA S-61-402, suitable for direct burial.
2.9 Roundness:
Cable to be round and smooth with no convolutions.
2.10 O.D.:
.375”
2.11 Surface Printing:
“2 Pr. 18 AWG Shld D/B Paige P7171D.”