| 1.0 |
SCOPE |
|
1.1 |
This specification covers a multi-pair direct
burial shielded cable designed to carry signals for Irrigation Control Equipment. |
| 2.0 |
CONSTRUCTION |
|
2.1 |
|
| |
NO. OF
PAIRS |
NO. OF
COND. |
SIZE
(AWG) |
STRANDS |
INSULATION
WALL |
| 2 |
4 |
18 |
7 |
.015" HIGH
DENSITY PE |
|
|
2.2 |
Conductor: |
|
|
Stranded soft annealed tin coated copper
conforming to ICEA S-56-434. |
|
2.3 |
Insulation: |
|
|
High density Polyethylene conforming to ICEA
S-56-434. |
|
2.4 |
Cable Assembly: |
|
|
Insulated conductors are twisted into a pair
and the cabled together. |
|
2.5 |
Color Coding: |
|
|
Pair 1 - Red, Black
Pair 2 - Blue, Orange |
|
|
| 2.6 |
Shield: |
|
.00235" aluminum/mylar tape helically
applied. |
| 2.7 |
Drain Wire: |
|
A 20 AWG tinned copper drain wire is laid in
under the shield in contact with the aluminum side. |
| 2.8 |
Jacket : |
|
.045" PE jacket conforming to ICEA
S-61-402, suitable for direct burial. |
| 2.9 |
Roundness: |
|
Cable to be round and smooth with no
convolutions. |
| 2.10 |
O.D.: |
|
.375 |
| 2.11 |
Surface Printing: |
|
2 Pr. 18 AWG Shld D/B Paige
P7171D. |
|