1.1 |
This specification covers requirements for
a direct burial shielded multiconductor cable designed to transmit
signals or power between satellites, central controllers, central
computers, and sensing devices for irrigation systems. The cable
utilizes stranded insulated conductors, an aluminum shield and drain
wire to protect signals from electrical, magnetic or RF interference,
and a sunlight resistant PE outer jacket. The cable is UL listed and
rated at 30 volts and 60°C. |
| 2.0 |
CONSTRUCTION: |
|
2.1 |
|
NO.
OF
COND. |
SIZE |
STRAND |
INSULATION
WALL
(MILS) |
JACKET |
WEIGHT
LBS/MFT |
WALL
(MILS) |
O.D.
(IN.) |
| 2 |
16 |
7 |
16 |
45 |
.300 |
50 |
|
|
2.2 |
Color Code:
Yellow, Grey: |
|
2.3 |
Conductors:
Stranded soft annealed tin coated copper conforming to ASTM-B-3 and B-8. |
|
2.4 |
Insulation:
Polyethylene conforming to ICEA S-61-402 and ASTM D-1248. |
|
|
|
The insulated conductors and the drain wire
are twisted together with a 3" maximum lay. Non-hydroscopic fillers are
inserted in the valleys to ensure roundness. |
| 2.6 |
Shield:
A 2 mil aluminum backed polyester shielding with a #16 AWG solid tinned copper drain wire
in contact with the aluminum side with a 25% minimum overlap. |
| 2.7 |
Jacket:
Black heat stabilized, high density low molecular weight Polyethylene, sunlight and
moisture resistant, conforming to ICEA S-61-402, NEMA WC5 and ASTM D-1248. |
| 2.8 |
Surface Print:
Paige P7162D No. of conductors size 30V shielded direct burial (UL), Tuf-hide®.
On opposite side ink print sequential footing. |
| 2.9 |
Paige Part Number:
180095TH
NOTE: For use on Toro Control Systems. |
|