P.O. Box 368, Union, NJ 07083-0368, 908-687-7810, 800-327-2443, Fax: 908-687-8860

PDF Download printable PDF version
DIRECT BURIAL Tuf-hide®
POWER OR CONTROL CABLE
INSULATION: PE
SHIELD: ALUMINUM BACKED POLYESTER
JACKET: SUNLIGHT RESISTANT PE
SIZES: 16 AWG
Ullogo.gif (224 bytes)
1.0 SCOPE: 2.5 Cable Assembly:
1.1 This specification covers requirements for a direct burial shielded multiconductor cable designed to transmit signals or power between satellites, central controllers, central computers, and sensing devices for irrigation systems. The cable utilizes stranded insulated conductors, an aluminum shield and drain wire to protect signals from electrical, magnetic or RF interference, and a sunlight resistant PE outer jacket. The cable is UL listed and rated at 30 volts and 60°C.
2.0 CONSTRUCTION:
2.1
NO. OF
COND.
SIZE STRAND INSULATION
WALL
(MILS)
JACKET WEIGHT LBS/MFT
WALL
(MILS)
O.D.
(IN.)
2 16 7 16 45 .300 50
2.2 Color Code:
Yellow, Grey:
2.3 Conductors:
Stranded soft annealed tin coated copper conforming to ASTM-B-3 and B-8.
2.4 Insulation:
Polyethylene conforming to ICEA S-61-402 and ASTM D-1248.
The insulated conductors and the drain wire are twisted together with a 3" maximum lay.  Non-hydroscopic fillers are inserted in the valleys to ensure roundness.
2.6 Shield:
A 2 mil aluminum backed polyester shielding with a #16 AWG solid tinned copper drain wire in contact with the aluminum side with a 25% minimum overlap.
2.7 Jacket:
Black heat stabilized, high density low molecular weight Polyethylene, sunlight and moisture resistant, conforming to ICEA S-61-402, NEMA WC5 and ASTM D-1248.
2.8 Surface Print:
Paige P7162D No. of conductors size 30V shielded direct burial (UL), Tuf-hide®. On opposite side ink print sequential footing.
2.9 Paige Part Number:
180095TH