| 1.0 |
SCOPE: |
| |
1.1 |
This specification covers requirements for
an underground shielded cable designed
to transmit and receive signals between
irrigation satellites, central computers,
weather stations, and sensors. The cable
utilizes stranded insulated conductors,
aluminum shield and drain wire to minimize
electrical, magnetic, and radio frequency
interference. The cable is listed
by UL or ETL or CSA. |
| |
|
|
| 2.0 |
CONSTRUCTION: |
| |
2.1 |
NO.
OF
COND. |
SIZE |
STRAND |
INSULATION
WALL
(MILS) |
JACKET |
WEIGHT
LBS/MFT |
WALL
(MILS) |
O.D.
(IN.) |
| 2 |
16 |
7 |
16 |
45 |
.300 |
50 |
|
| |
2.2 |
Conductors: |
| |
|
Stranded soft annealed tin coated copper
conforming to ASTM-B-3 and B-8. |
| |
2.3 |
Insulation: |
| |
|
PVC, yellow and gray. |
| |
2.4 |
Cable Assembly: |
| |
|
The insulated conductors and the drain
wire are twisted together with a 3” maximum
lay. Non-hydroscopic fillers are inserted
in the valleys to ensure roundness. |
| |
|
|
|
|
| |
2.5 |
Shield: |
| |
|
A 2 mil aluminum backed polyester
shielding with a #16 AWG solid
tinned copper drain wire in contact
with the aluminum side with a 25%
minimum overlap. |
| |
|
|
| |
2.6 |
Jacket: |
| |
|
Black Polyethylene, sunlight and moisture
resistant. |
| |
|
|
| |
2.7 |
Surface Print: |
| |
|
PAIGE ELECTRIC P7162D LISTING
AGENCY AND NUMBER 16 AWG
1PR SHIELDED 30V SPRINKLER SYSTEMS
WIRE AND/OR UNDERGROUND
LOW ENERGY CIRCUIT
CABLE RoHS COUNTRY OF ORIGIN.
SEQUENTIAL FOOTING EVERY 2’. |
| |
2.8 |
Paige Part Number: |
| |
|
180095TH
NOTE: Compatible with Toro Control
Systems, Weather Stations, and sensor
circuits.. |
|