DBY/DBR and DBY-6/DBR/6

Direct Bury Splice Kits

csa.gif (1422 bytes)     ullogo.gif (1157 bytes)

Db2.jpg (27579 bytes)

3M Has Your Wiring Needs Covered
3M DBY/DBR Direct Bury Splice Kits are real time savers when installing underground electrical systems. Every component for the splice is included in the kit. The insulator tube is pre-filled, eliminating the chance of the installer using too much or too little sealant.
No crimping tools, no waste, no mess. Just quick, reliable underground splices for irrigation and sprinkler systems, landscape lighting and other  underground projects. The splice may be re-entered without cutting the wires (new tube required)
Flexibility
  • The DBY and DBY-6 splice kit connects a wire range of 2-5 #18 AWG through 2 #12 plus 1 #16 AWG solid or stranded copper wire.
  • The DBR and DBR-6 splice kit connects a wire range of 5 #16 AWG through 3 #10 AWG solid or stranded copper wire.
  • Sealant does not set up hard, allowing splice to be reworked without cutting wires (new tube required).
  • Application temperature range:
    32  - 120F (0 - 49C).
  • Storage Temperature: 120F (49C) maximum.
  • Non-U.V. Stable
Economy   
  • Insulating gel is already contained in the tube.
  • Long-term electrical properties reduce callbacks and rework.

Dependability

  • Locking fingers in the tube ensure that the Scotchlok™ connector (twist-on wire connector) stays in position.
  • The closed tube cover provides strain relief
  • Design protects against corrosion failure.

 

The Scotchlok™ Y and R connectors (twist-on wire connectors) are UL listed. When assembled in the tubes of the DBY-6 and DBR-6 products, the splices are UL listed for 600 volts maximum as a wire connector system for use with underground conductors.
Product Wire Range Voltage Rating Agency Listing
DBY 18-12 AWG 30V -
DBR 16-10 AWG -
DBY-6 18-12 AWG 600V UL, CSA
DBR-6 16-10 AWG UL, CSA
For Use In:
  • Sprinkler Systems
  • Outdoor Lighting
    (Decks, driveways, lamp posts, landscape)
  • Septic Systems
  • Golf Courses
  • Other underground electrical wiring applications
Easy as 1, 2, 3
Db1-1.jpg (4588 bytes) 1. Strip wires, apply the Scotchlok electrical connector and twist in a clockwise direction. Db1-2.jpg (5857 bytes) 2. Insert the splice into the gel-filled insulator tube. Push past the locking fingers to hold the Scotchlok connector in place. Db1-3.jpg (6930 bytes) 3. Position wire channels and snap insulator tube cover closed.
3M and Scotchlok are trademarks of 3M.
csa.gif (1422 bytes) ullogo.gif (1157 bytes)
Listed
98U1

 

IMPORTANT NOTICE TO PURCHASER:
All statements, technical information and recommendations related to the Seller's products are based on information believed to be reliable, but the accuracy or completeness thereof is not guaranteed. Before utilizing the product, the user should determine the suitability of the product for its intended use. The user assumes all risks and liability whatsoever in connection with such use.
All statements or recommendations of the Seller which are not contained in the Seller's current publications shall have no force or effect unless contained in an agreement signed by an authorized officer of the Seller. The statements contained herein are made in lieu of all warranties expressed or implied, including but not limited to the implied warranties of merchantability and fitness for a particular purpose which warranties are hereby expressly disclaimed.

3M 1993

SELLER SHALL NOT BE LIABLE TO THE USER OR ANY OTHER PERSON UNDER ANY LEGAL THEORY, INCLUDING BUT NOT LIMITED TO NEGLIGENCE OR STRICT LIABILITY, FOR ANY INJURY OR FOR ANY DIRECTOR CONSEQUENTIAL DAMAGES SUSTAINED OR INCURRED BY REASON OF THE USE OF ANY OF THE SELLER'S PRODUCTS.
3M Electrical Products Division
6801 River Place Blvd.
Austin, Texas 78726 - 9000

3M