CABLE TYPE |
CONNECTION CHOICES |
 Rain Bird "Maxi Cable" |
14 AWG, 2 Conductors
12 AWG, 2 Conductors |
- 3M #DBO/B-6 (Paige 270674) or #DBR/Y-6 (Paige 270672)
- RE-ENTERABLE CONNECTORS (PAIGE P7408D)a
|
 TORO P7162D |
16 AWG, 2 Conductors, Drain wire, Unarmored |
- Paige Electric Splice Kit, Spec' P273210D, includes: 3M #82-A1, Split bolt, and Butt Connectors (2 each)
- 3M #SLiCTM (Paige 273211) with 3 each 3M 316IR (Paige 270228R). Use #8 split bolt (Paige 181994) to re-connect armor.
|
 TORO P7162D-A |
16 AWG, 2 Conductors, Drain wire, Armored |
 HUNTER P7171D |
18 AWG, 2 Pairs, Drain wire, Unarmored |
3M #SLiCTM (Paige 273211) with 5 each 3M #316IR (Paige 270228R) or 3M #UR-2 (Paige 270286). Use #8 split bolt (Paige 181994) to re-connect armor. |
 HUNTER P7171D-A |
18 AWG, 2 Pairs, Drain wire, Armored |
 PE-39/PE-89/PE-54 |
3 Pair, 19 AWG |
3M #SLiCTM with 6 each 3M #316IR (Paige 270228R) or 3M #UR-2 (Paige 270286). Use #2 Split Bolt (Paige 181997) to re-connect the aluminum shield |
 PE-39/PE-89/PE-54 |
6 Pair, 19 AWG |
3M #8882, Size D (Paige 278064) with 12 each 3M #UR-2 (Paige 270286). Use #2 Split Bolt (Paige 181997) to re-connect the aluminum shield |
a) Re-enterable connctors are available in the following configurations. From 2 to 6 wires can be connected in a single splice
(eg: 4 black decoder wires on the 270RC4)
Use 270RC2 for connecting 2/3/4/5/6 wires
b) Connectors Listed (under UL486D-Direct Burial): DBO/B-6, DBR/Y-6, Re-enterable Connectors,
Silicone-filled Wire Nuts, 82-A, 82-A1, 82-A2, and 82-A3.
c) For specific details on each product, visit our website at: www.paigewire.com